Fecha: 03/07/2006 Revisión: -- Observaciones: Página: 0009 / 0023 Tomo: 01 / 02 Puntal TC 4m tornillería M16x40 Puntal TC 4m Puntal TC 4m Puntal TC 2m Puntal TC 4m Puntal TC 0,67m Puntal TC 2m 7,50 m 4,50 m 6,0 m 3,0 m Mod. Longitud (rango) m. Cabezal Base 3kg Bulón 127 + Grapa - 0, 4 kg Husillo Izq. 40 cm - 6 kg Husillo Der. 40 cm – 6 kg Tornillería M16 x 40 Puntal E. 0,67m - 8, 8kg Puntal E. 2,0m - 26,2kg Puntal E. 4m - 51,4kg Peso total Kg 1 0, 95 - 1, 50 ½ 2 1 1 1 24,5 2 1, 55 - 2, 20 ½ 2 1 1 4 2 34 3 2, 17 - 2, 82 ½ 2 1 1 1 42 4 2, 86 - 3, 51 ½ 2 1 1 4 1 1 51,5 5 4, 19 - 4, 84 ½ 2 1 1 4 2 69 6 4, 19 - 4, 84 ½ 2 1 1 1 67 7 4, 89 - 5, 54 ½ 2 1 1 4 1 1 76,5 8 6, 20 - 6, 85 ½ 2 1 1 4 1 1 94 9 8, 22 - 8, 87 ½ 2 1 1 4 2 119 Cuña fijación Correa 0,9 orej. Puntal TC 4m Puntal TC 2m Correa 3 orej. Altura m. Ancho unitario m. Modulos a utilizar Mod. 3 3 1+3 4,50 3 1+6 6 3 1+3+3+8 7 3 1+1+3+3+6 +6+9+9 Cantidad de Puntales Estabilizadores Puntal TC 2m Cabezal Base Husillo Tc 40cm Der. MANUAL MONTAJE puntales estabilizadores www.baygar.com