Fire door frames
Archive · 2012 It may be out of date; ask us before you decide.
Swipe to turn the page
To see the page exactly as printed, open it in the PDF. Open the PDF at page 16
Text of page 16
Kit for EI2 60; it will be installed into plasteboard partitions of minimum wall thickness of 125mm. It consists of the following: -Preparation of the standard door frame for screw fixing. -Intumescent seals; for interior frame 30 x 2 mm and 20 x 2mm. -“T” piece for fixing the metallic profiles into the wall (12 units). -Screws for fixing the frame, “T” piece and wall metallic profiles Available for doors with dimensions up to: 1090 x 2230 single leaf Available for doors with dimensions up to: 2230 x 2230 double door PLASTEBOARD PARTITION KIT PARTS DETAILS KIT EI2 60 DETAILS KIT EI2 120 PERFIL EN "T" PERFIL EN "T" INTUMESCENT SEAL 30x2 INTUMESCENT SEAL 30x2 Kit for EI2 120; it will be installed into plasteboard partitions minimum wall thickness of 150mm It consists of the following: -Preparation of the standard door for MC3 frame screw fixing. -Intumescent seals; for interior frame 30 x 2 mm -“T” piece for fixing the metallic profiles into the wall (14 units). -Screws for fixing the frame, “T” piece and wall metallic profiles. KIT CARTÓN- YESO INTUMESCENT SEAL 20x2 INTUMESCENT SEAL 30x2 "T" PROFILE "T" PROFILE 133 Plasteboard partition: they are a set of accessories that make possible the installation of doors into plasteboard partitions, following the approved certificates. Note: the plasteboard partition must be built according to the instructions given by Padilla Fire Doors S.L. The structure of the partition must be consistently reinforced especially in both sides and crossbeam of the aperture where the door will be installed in order to reach a mechanical strength without impacting on the fire protection properties. To achieve these results, it is very important to use support profiles of a minimum thickness of 2 or 3 mm securely fixed to the door set frame. It also has to be ensured that the unit is firmly fixed to the floor, at the bottom, and into the ceiling at the head with fixings of sufficient strength to carry the loads into the primary structure, taking special attention when the height of the wall exceed 2.700mm. Fixation screws Fixation screws www.baygar.com