SECTION A-A’ Model Nominal Measurement Light Measurement Frame Measurement Total Measurement CS65 frame Width Height Width Height Width Height Width Height VH 1000 x 2208 1036 2208 900 2100 1036 2208 1036 2208 VH 1100 x 2208 1136 2208 1000 2100 1136 2208 1136 2208 VH 1200 x 2208 1236 2208 1100 2100 1236 2208 1236 2208 MEASUREMENTS ONE LEAF SECTION B-B’ Standard measurements in millimeters. Possibility of other measurements on request. A A’ B B’ TOTAL MEASUREMENT TOTAL MEASUREMENT LIGHT MEASUREMENT FRAME MEASUREMENT NOMINAL MEASUREMENT TOTAL MEASUREMENT CS65 TOTAL MEASUREMENT LIGHT MEASUREMENT FRAME MEASUREMENT NOMINAL MEASUREMENT CORNER FRAME Organisms test cfu*/ Control Surface 0 hours cfu*/ Control Surface 24 hours cfu*/ Control Surface 24 hours Reduction [log] Reduction [%] Staphylococcus aureus 8.17 x 106 1.06 x 106 < 100 4.03 > 99.99 Escherichia coli 9.93 x 106 1.66 x 106 < 100 4.22 > 99.99 Candida albicans 6.30 x 106 4.27 x 104 < 100 2.63 > 99.77 Aspergillus brasiliensis 4.33 x 104 2.25 x 105 < 100 3.35 > 99.96 MICROBIAL ACTIVITY Anti-microbial activity test in the HPL Formica sheets. 94 wwww.baygar.com