Saltar al contenido
Buscar en los catálogos

Busca en el texto de todos los catálogos: te llevamos a la página exacta.

Idioma: Español
Contacto

Inicio Fichas técnicas Encofrado perdido y hormigón Encofrado para cubierta ventilada Iglu

Daliform

Encofrado para cubierta ventilada Iglu

Descargar PDF en inglés, 6 págs. Abrir el PDF completo

Para ver la página tal como está en el catálogo, ábrela en el PDF. Abrir el PDF en la página 4

Texto de la página 4

4 4 50x50 3 3 3 0,004 0,770 110x110x110 310 400 100 50x50 2,2 2,2 2,2 0,006 0,800 110x110x252 500 600 150 4 50 A B B h 50 h A B B 50 50 a b h 50 50 (57,8) (71) DALIFORM GROUP Advantages Technical details The realization of a ventilated roof (fl at and pitched roof) with Iglu'® ventilated roof provides greater living comfort both in winter and summer, as well as improving the conservation of the materials forming the roof. - In the winter months, closing the ventilation with a simple register, it can isolate from the cold outside. - In the summer months it can reduce heating of the spaces below thanks to ventilation. - The ventilation also avoids moisture stagnation below the roof surface and thus prevents the formation of mold or other substances which may lead to a degradation of the structure. - Significant savings on energy consumption (heating/cooling). The height of the interspace is to be determined in function of the technical characteristics of the roof, such as the type of coverage, the length and slope of the pitch and the local weather conditions. Tests have been performed on roof ventilation using Iglu'® ventilated roof, in collaboration with the University of Malta, which have provided very valid results, combining a summer ventilation system with the closure of air inlets in winter, in order to create an insulating cavity. In the winter, a condensation vacuum tied to specifi c registers can be prepared to avoid excess moisture inside the cavity. The material does not fear the bad weather and therefore it can be stored outside. * In consideration of the recycled material, it is permitted a size tolerance of 2.5%. ** The volume may vary depending on the pouring condition and the tolerance of the material. Iglù® linea : model with rib cross on the dome. Depending on the different heights, the shape of the formwork may differ from those depicted. Useful dimensions * Height h tunnel clearance Pipe A max diameter Pipes B max diameter Quantity of concrete to the crown** Weight of each unit Pallet dimensions cm h cm 1 x Ø cm 2 x Ø cm m3/m2 Kg. a x b x h Kg. Units Sqm H cm Cutaway of a fl at roof ventilated with Iglu’® ventilated roof Cutaway of a pitched roof ventilated with Iglu’® ventilated roof www.baygar.com